Availability: | |
---|---|
Quantity: | |
Performance Characteristics:
1.New blade design, the continuation of the previous generation of high overload and high precision at the same time,
to achieve the horizontal surface reduction, which is conducive to space-saving,convenient for users to install and use;
2.With advanced motor parameters self-learning function, support for asynchronous and synchronous motors;
3.8-way multi-function input terminals, with 52 kinds of customized terminal functions, to achieve flexible multi-function control;
4.Timing operation function, timing operation can be up to 6500Min; with pendulum frequency control function, pendulum frequency
function parameters can be adjusted by the user; built-in simple PLC, programmable16-segment speed operation, each section of the
running time,acceleration and deceleration time are independently adjustable.
Three-phase 380V | |||||||||||||
Frame size | E | F | G | H | I | ||||||||
Type LD500- T4 | 030 | 037 | 045 | 055 | 075 | 090 | 110 | 132 | 160 | 185 | 200 | ||
Applicable motor power KW | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 200 | ||
Applicable motor horsepower HP | 40 | 50 | 60 | 75 | 100 | 125 | 150 | 180 | 220 | 250 | 275 | ||
output | Rated output capacity KVA | 40 | 57 | 69 | 85 | 114 | 134 | 160 | 192 | 231 | 244 | 250 | |
Rated output current A | 60 | 75 | 91 | 112 | 150 | 176 | 210 | 253 | 304 | 340 | 377 | ||
Output frequency Hz | 0.01--400Hz | ||||||||||||
Carrier frequency range KHz | 1--16KHz | ||||||||||||
Overload capacity | 150% of rated output current, can withstand 60S | ||||||||||||
200% of rated output current, can withstand 3S | |||||||||||||
input | Input current A | 62 | 76 | 92 | 113 | 157 | 180 | 214 | 256 | 307 | 350 | 385 | |
Input voltage frequency | AC:three-phase 380V.50/60Hz | ||||||||||||
Permissible voltage fluctuations | (-15%--+15%) | ||||||||||||
Cooling system | Forced cold air |
Three-phase 380V | |||||||||||
Frame size | I | J | K | L | |||||||
Type LD500- T4 | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | ||
Applicable motor power KW | 220 | 250 | 280 | 315 | 355 | 400 | 450 | 500 | 560 | ||
Applicable motor horsepower HP | 300 | 340 | 380 | 430 | 485 | 545 | 615 | 680 | 760 | ||
output | Rated output capacity KVA | 280 | 355 | 396 | 445 | 500 | 565 | 630 | 700 | 780 | |
Rated output current A | 426 | 465 | 520 | 585 | 650 | 725 | 820 | 910 | 1020 | ||
Output frequency Hz | 0.01--400Hz | ||||||||||
Carrier frequency range KHz | 1--16KHz | ||||||||||
Overload capacity | 150% of rated output current, can withstand 60S | ||||||||||
200% of rated output current, can withstand 3S | |||||||||||
input | Input current A | 430 | 468 | 525 | 590 | 665 | 785 | 883 | 940 | 1062 | |
Input voltage frequency | AC:three-phase 380V.50/60Hz | ||||||||||
Permissible voltage fluctuations | (-15%--+15%) | ||||||||||
Cooling system | Forced cold air |