Availability: | |
---|---|
Quantity: | |
High Quality Design
Wide Voltage Design in line with International Standards
Various EMC Specifications and Solutions
Complete DC Braking Circuit Solution
Long Life Design
Independent Air Duct Design
International IEC Standard Design
Excellent Performance
Good Voltage and Current Control
Overvoltage Stall&Overcurrent Stall
Excellent Parameter Self-learning Function
It can accurately perform self-learning of rotating or static motor parameters, is easy to debug, simple to operate, and providing higher control accuracy and response speed.
Multi-point Voltage and Flux Setting Function
LD350()S2 | 0R7 | 1R5 | 2R2 | 4R0 | 5R5 | 7R5 |
KW | 0.75 | 1.5 | 2.2 | 4 | 5.5 | 7.5 |
Frame size | A | B | C |
LD350()T4 | 0R7 | 1R5 | 2R2 | 4R0 | 5R5 | 7R5 | 011 | 015 | 018 | 022 |
KW | 0.75 | 1.5 | 2.2 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 |
Frame size | A | B | C | D |
LD350()T4 | 030 | 037 | 045 | 055 | 075 | 090 | 110 | 132 | 160 | 185 | 200 |
KW | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 200 |
Frame size | E | F | G | H |
220V | |||||||
Frame size | A | B | C | ||||
Type 1D250- S2B | 0R7 | 1R5 | 2R2 | 4R0 | 5R5 | 7R5 | |
Applicable motor power KW | 0.75 | 1.5 | 2.2 | 4 | 5.5 | 7.5 | |
Applicable motor horsepower HP | 1 | 2 | 3 | 5 | 7.5 | 10 | |
output | Rated output capacity KVA | 1.9 | 2.5 | 4.2 | 6.5 | 9.5 | 12.5 |
Rated output current A | 4 | 7 | 9.6 | 17 | 25 | 30 | |
Output freauency Hz | 0.01--400Hz | ||||||
Carrier frequency range KHz | 1--16KHz | ||||||
Overload capacity | 150% of rated output current, can withstand 60S | ||||||
200% of rated output current, can withstand 3S | |||||||
input 220V | Inpul current A | 7 | 9.4 | 14 | 21 | 26 | 31 |
Iput voltage frequenc | single phase220V,50/60Hz | ||||||
Permissible voltage fluctuations | (-15%--+15%) | ||||||
Cooling system | Forced cold air | ||||||
Brake unit | built-in |
380V | |||||||||
Frame size | A | B | C | ||||||
Type LD350- T4B | 0R7 | 1R5 | 2R2 | 4R0 | 5R5 | 7R5 | 011 | 015 | |
Applicable motor power KW | 0.75 | 1.5 | 2.2 | 4 | 5.5 | 7.5 | 11 | 15 | |
Applicable motor horsepower HP | 1 | 2 | 3 | 5 | 7.5 | 10 | 15 | 20 | |
output | Rated output capacity KVA | 2.3 | 3.2 | 4.2 | 6.5 | 9.9 | 13.7 | 18.3 | 24.4 |
Deted wdrwt eawrenl A | 2.1 | 3.8 | 5.1 | 9.0 | 13 | 17 | 25 | 32 | |
Output frequency Hz | 0.01--400Hz | ||||||||
Carrier frequency range KHz | 1--16KHz | ||||||||
Overload capacity | 150% of rated output current, can withstand 60S | ||||||||
200% of rated output current, can withstand 3S | |||||||||
input | Input current A | 3.2 | 4.3 | 5.9 | 11.2 | 14 | 29 | 25 | 32 |
Input voltage frequency | three-phase 380V,50/60Hz | ||||||||
Permissible voltage fluctuations | (-15%--+15%) | ||||||||
Codling system | Forced cold air | ||||||||
Brake uni | built-in |
380V | ||||||||||||||
Frame size | D | E | F | G | H | I | ||||||||
Type LD350- T4B | 018 | 022 | 030 | 037 | 045 | 055 | 075 | 090 | 110 | 132 | 160 | 185 | 200 | |
Applicable motor power kW | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 185 | 200 | |
Applicable motor horsepower HP | 25 | 30 | 40 | 50 | 60 | 75 | 100 | 125 | 150 | 176 | 215 | 250 | 275 | |
output | Rated output capacity KVA | 29 | 43 | 46 | 56 | 69 | 84 | 114 | 143 | 175 | 200 | 300 | 282 | 310 |
Rated output current A | 37 | 45 | 60 | 75 | 90 | 110 | 152 | 176 | 210 | 253 | 304 | 345 | 380 | |
Output frequency Hz | 0.01--400Hz | |||||||||||||
Carrier frequency range KHz | 1--16KHz | |||||||||||||
Overload capacity | 150% of rated output current, can withstand 60S | |||||||||||||
200% of rated output current, can withstand 3S | ||||||||||||||
input | Input currontA | 50 | 54 | 58 | 70 | 90 | 105 | 140 | 165 | 200 | 240 | 290 | 330 | 370 |
Input voltage frequency | three-phase 380V.50/60Hz | |||||||||||||
Permissible voltage fluctuations | (-15%--+15%) | |||||||||||||
Cooling system | Forced cold air |
characteristic parameter | ||||
project | specifications | |||
IN-OUT | analog input | 2-way/voltage current signal switchable, voltage 0-10V,current 0-20mA | ||
Digital input | 5 channels/optocoupler isolation, including 1 high-speed pulse input, with a maxinum input pulse frequency of up to 100KHz | |||
analog output | 2 channels/voltage output range 1-10V, current output range 0-20mA, output signal type can be switched | |||
Digital output | 2-way/optocoupler isolation/open collector output/rated current 20mA (DO, HDO) | |||
Digital pulse output | 2 channels/optocoupler isolation/open collector pulse (frequency or PWM) output (DO, HDO), including1 channel of high-speed pulse output, the maximum output pulse frequency can reach 100KHz | |||
relay output | 2-way/Normally Open and Normally Closed Contact/250VAC-3A | |||
communication mode | Standard MODBUS-485 communication protocol | |||
control characteristic | control mode | V/F control; PG free vector control (SVC) | ||
Frequency setting mode | Multple setting methods such as keyboard setting, analog quantity seting, pulse setting, communication setting, etc | |||
Freduency control range | 0.01-400.00Hz | |||
Frequency control accuracy | Digital setting: 0.01Hz; Analog setting: maximum frequency x 0.025% | |||
speed range | 1:200(SVC); 1:1000(FVC) | |||
Steady range | ±0.5%(SVC);±0.02%(FVC) | |||
Acceleration and deceleration time | 1.0-3600.0 seconds (acceleration and deceleration times can be set separately, and S characteristics can be switched) | |||
Inching control | Point frequency range: 0.00Hz-100.00Hz; Point acceleration time: 0.0s-3600s | |||
Starting torque | 0.5Hz 150%(SVC) adjustable, considering the capacity of the frequency converter; 3.0Hz 100%(V/F) | |||
Torque boost | Automatic torque increase; Adjustable manual torque increase of 0.1%-30.0% | |||
braking torque | Braking resistance braking (125%), DC braking (20%) | |||
DC braking | Braking time: 0.0s-36.0s; Braking current: 0.0%-100.0% | |||
timing control | Timing range: 0.0min-6500min | |||
Pid control | Built in PIO function for convenient closed-loop control of processes | |||
V over F curve | Linear, multi-point custom curve, 1.1-2.0 arbitrary descent curve | |||
Multi stage speed control | Buit-in simple PLC can control the maximum 16 speed frequency logic | |||
Carrier adjustable | Adjustable from 1.0 to 16.0kHz, adjustable according to module temperature | |||
Frequency setting signal | -10-+10,0-+10,4-20mA, high-frequency pulse, PWM pulse | |||
protection function | Overload capacity | G:150% 60s 200% 3s | ||
Instantaneous overcurrent /short circuit protection | Automatically cut off output when the rated output current exceeds 200% | |||
Overyoltage/secondary voltage protection | When the DC voltage of the bus is too low (360V) or too high (800V), the motor stops freely (except during braking) | |||
Phase loss protection | When there is a phase loss at the input or output end, the motor stops freely | |||
Overheat protection | When the radiator temperature is ≥85 ℃, the motor stops freely; The temperature protection threshold can be freely set according to the ambient temperature | |||
motor protection | Analog input can be connected to temperature sensor inputs (PT100,PT000) to achieve motor overheating protection | |||
Stall protection | Using current sensors to detect stall prevention during acceleration and deceleration, and stall prevention during operation (acion current can be set) | |||
ground protection | Using current sensors for detection | |||
Instant stop | By compensating for voltage reduction through load feedback energy, the frequency converter can maintain continuous operation for a short period of time | |||
specifications stucture | Rated input | voltage:1/3PH 220V±20%;3PH 380V±20%;frequency:50Hz/60Hz±5% | ||
Cooling and protection | ≤18.5kW:IP20;>18.5kW:1IP10;Forced air cooling | |||
Usage environment | Temp:-10℃-+40℃ altitude: Not higher than 1000m; Indoor,without corrosive gases | |||
Save Environment | Temp:-20℃-+65℃ humidity: 20-90%RH(No condensation)The vibration is less than 6m/S squared(0.6g) |