Electrical specifications for single-phase 220V rated drives
Item | SIZE A | ||
Drive Model | 1R6B | 2R8B | 5B5B |
Drive power (kW) | 0.2 | 0.4 | 0.75 |
Maximum applicable motor capacity (kW) | 0.2 | 0.4 | 0.75 |
Continuous output current (A) | 1.6 | 2.8 | 5.5 |
Maximum output current (A) | 5.8 | 10.1 | 16.9 |
Main circuit power supply | Single-phase AC200V ~ 240V, -15 ~ +10%, 50/60Hz | ||
Control circuit power supply | Single-phase AC200V ~ 240V, -15 ~ +10%, 50/60Hz | ||
Brake Drain Function | External braking resistor, internal braking resistor |
Three-phase 220V rated drive electrical specifications
Item | SIZE A | SIZE C | |
Drive Model | 5R5B | 7R6B | 012B |
Drive power (kW) | 0.8 | 1 | 1.5 |
Maximum applicable motor capacity (kW) | 0.8 | 1 | 1.5 |
Continuous output current (A) | 5.5 | 7.6 | 11.6 |
Maximum output current (A) | 16.9 | 17 | 28 |
Main circuit power supply | Three-phase AC200V~240V, -15~+10%,50/60Hz | ||
Control circuit power supply | Single-phase AC200V ~ 240V, -15 ~ +10%, 50/60Hz | ||
Brake Drain Function | Built-in braking resistor |
Three-phase 380V rated drive electrical specifications
Three-phase 380V rated drive electrical specifications | |||||||
Item | SIZE C | SIZE E | |||||
Drive Model | 2850 | 5R4D | 8R4D | 012D | 017D | 021D | 026D |
Drive power (kW) | 1 | 1.5 | 2.2 | 3 | 4 | 5.5 | 7.5 |
Maximum applicable motor capacity (kW) | 1 | 1.5 | 2.2 | 3 | 4 | 5.5 | 7.5 |
Continuous output current (A) | 3.5 | 5.4 | 8.4 | 11.9 | 16.5 | 20.8 | 25.7 |
Maximum output current (A) | 8.5 | 14 | 20 | 24 | 42 | 55 | 65 |
Main circuit power supply | Three-phase AC380V ~ 440V,-15 +10%, 50/60Hz | ||||||
Control circuit power supply | Single-phase AC380V~440V,-15~+10%,50/60Hz | ||||||
Brake Drain Function | Built-in braking resistor |
Specification | |||
Item | Standardize | ||
Control method | 220V,380V: single-phase or three-phase full-wave rectification | ||
IGBT PWM controlled sinusoidal current drive method | |||
feedback | 20bit / 23bit Bus Incremental Encoder 23bit Bus Multi Absolute Encoder | ||
Conditions of use | Use/storage temperature (Note 1) | 0~+45° C (Please use at a reduced rating if the ambient temperature is above 45° C) 1-40~+70° C | |
Use/storage humidity | Below 90% RH (no condensation) | ||
Vibration/shock resistance | 4.9m/s²/19.6m/s2 | ||
Protection class | P10 | ||
Contamination level | Level 2 | ||
Altitude | Less than 1000m | ||
Property | Rate of change in speed (Note 2) | Rate of load variation | 10100% load: less than 0.5% (at rated speed) |
Rate of voltage variation | Rated voltage 10%:0.5%(at rated speed) | ||
Temperature variation rate | 25±25℃: below 0.5% (at rated speed) | ||
Sushui control Fan Min | 1:500 (the lower limit of the speed control range is the condition that the rated torque load does not stop) | ||
Frequency characteristic | S620P:1.2kHz | ||
Torque control accuracy (repeatability) | ±2% | ||
Soft start time setting | 060s(Acceleration and deceleration can be set separately) |
Speed torque control mode | |||
Item | Standardize | ||
Input signal | Speed instruction input | Command voltage | DC±10v, usually 12 bits, up to 16 bits (16 bit resolution analog input port is non-standard) |
Input voltage: Max 12V(positive command when the motor is turning)(Note 3) | |||
Input resistance | About 9kQ | ||
Circuit time parameter | About 47 μs | ||
Command voltage | DC±10V, usually 12 bits, up to 16 bits (16 bit analog input port is non-standard) | ||
Input voltage: Max 12V(positive torque instruction) | |||
Input resistance | About 9kQ | ||
Circuit time parameter | About 47 μs | ||
Multi-segment speed instruction | Speed selection | The signal combination of DI1(CMDI), DI2 (CMD2), DI7 (CMD3) and D18 (CMD4) is used to achieve the speed selection of the 16th segment. (Other terminals can be set for this function) | |
Property | Feedforward compensation | 0100%(set resolution 0.1%) | |
Positioning completes width setting | 065535 Instruction unit (set fraction 1 encoder unit) | ||
Input signal | Command pulse | Input pulse pattern | From the "direction ten oil impulse "," A, B phase orthogonal pulse ","CW/CCW pulse, in any wash a pump |
Input form | Differential input collector open | ||
Input pulse frequency | Differential input: high-speed maximum 4Mpps, dolphin width can not be less than 0.125u5 Low speed maximum 500Kpps, pulse width cannot be less than 1uS Open collector: maximum 200Kpps, pulse width can not be less than 2.515 | ||
Control signal | Clear signal (input form is the same as the command pulse) | ||
Internal collector open circuit power supply (Note 4) | +24V(built-in 2.4k0 positive) | ||
Multi-segment position instruction selection | Configure 4 D1s to function as CMDI, CMD2, CMD3, and CMD4 to achieve location selection in paragraph 116) |