30kW-360kW DC Charging post
Product Highlights | |||
Versatile | No need to expand capacity,realize virtual expansion of the power grid by itself;Peak shaving and valley filing,set the regular wiring of electricity according to the replenishment power;Sweep the code and use it,V2G reverse power replenishment. | Stabilise | Double insulation safety design;IP54 for the whole machine. |
Reliably | The service life of the whole machine is up to 8 years;The failure rate of the whole machine is less than 5 out of 10,000;the failure rate of keycomponents is less than 3 out of 10,000. | Adapter | Wide voltage platform (200V-750V).High power output (max.60kW for a single gun). |
Surety | Noise<55dB,suitable for indoor environment;Low electromagnetic radiation,residential grade EMC rating. | Efficiently | No need to take up parking space;high power fast charging; |
Application scenario | |
Tourist attraction Temporary,cyclical demand;high cost of expansion of existing distribution networks | Neighborhood and office space Expansion is difficult;Low noise,low radiation needs OEMs and 4S stores Wide range voltage platform matching High specification and vehicle compatibility |
Highway Service Area Inabilty to meet the charging demand in a given period;high cost of expansion of the existing distribution network. | Temporary exhibitions Temporary requirements,fast-forward and fast-absorption capacity is fixed and cannot be expanded |
Commercial buildings Customer traffic is centralized,the grid load is fixed in large capacity and cannot be expanded | Gas stations Oil and electricity supply at the same time,the first element of safety gas station grid capacity constraints |
Product Parameters | |
Product Classification | 30kW 60kW 90kW 120kW |
AC Input Voltage | AC380V±15% |
AC access method | three-phase, five-wire (PRC) |
AC Input Frequency | 50Hz±5% |
Maximum output power | 30kW 60kW 90kW 120kW |
Output Voltage Range | 200-750V |
Rated output current | 40A/60A 80A/120A 120A/180A 160A/240A |
Power factor | >0.98 (above 50% load) |
Combined efficiency | >95% (more than half load) |
Output Voltage Error | In constant voltage mode, the adjustment error of DC output voltage is not more than ±5%. |
Output current error | Under the constant voltage mode, the output DC current setting value is within 20%~100% of the rated value, and the output current calibration error does not exceed 1% when the output direct current is greater than or equal to 30A; and the output current calibration error does not exceed 3A when the set output DC current is less than 30A. |
Output ripple factor | ≤0.5% (RMS); <1% (peak) |
Starting inrush current | <110% of input current |
Auxiliary power | Common low-voltage auxiliary power supply for 12V/OA and 24V/1OA two modes can be selected at the same time with reverse protection, the ripple coefficient < 1%. |
Size of the whole machine | 650*331*1640mm 670*500*1670mm 670*500*1670mm 670*500*1670mm |
Protection class | IP54 |
Operating temperature | -20℃~+55℃ |