High Efficiency Conversion
Tri-level topology, with a maximum efficiency of 98.6%
IP21 protection rating, easy integration into all-in-one systems
Anti-islanding
Intelligent Collaboration
Compliant with Grid Dispatch Requirements,Responsive to Primary Frequency Regulation
Active and Reactive Power Adjustment,Supports Black Start Capability,
Compatible with IEC 61850 Protocol
Flexible Configuration
Supports PQ, VF, VSG, and other operating modes
Multiple Interface Configurationa
Supports parallel operation of multiple units.
Safe and Reliable
Compact size,high power density.
Wide temperature range operation, No frequency reduction at 45 degrees.
Multiple interlocking protection functions
Model | Orion030 | Orion040 | Orion050 |
DC characteristics | |||
Maximum DC Voltage | 800vdc | ||
Minimum DC Voltage | 600vdc | ||
DC Operating Voltage Range | 650~800vdc | 650~800vdc | 650~800vdc |
Maximum DC Current | 55A | 70A | 86A |
Number of DC Inputs channels | 1 | ||
AC characteristics (grid-connected) | |||
Rated Output Power | 30kW | 40kW | 50kW |
Maximum Output Power | 33kVA | 44kVA | 55kVA |
Maximum Output Current | 48A | 64A | 80A |
Rated Grid Voltage | 400Vac | ||
AC Voltage Range | -15%~10%(Adjustable Range) | ||
Rated Grid Frequency / Grid Frequency Range | 50Hz/45-55Hz(Configurable up to 60Hz) | ||
AC Current Harmonics | <3%Un(Based on Rated Output Power) | ||
Power Factor at Rated Power | >0.99(Based on Rated Output Power) | ||
Reactive Power Adjustable Range | -100%~100% | ||
Number of Feeding Phases/Number of Output Phases | 3-Phase/3-Wire | ||
Overload Capability | 110% Overload | ||
AC characteristics (off-grid) | |||
Rated Output Power | 30kW | 40kW | 50kW |
Maximum Output Power | 33kVA | 44KVA | 60kVA |
Maximum Output Current | 48A | 64A | 86A |
Rated AC Voltage | 400Vac | ||
AC Voltage Range | -15%~10%(Adjustable Range) | ||
AC Voltage Harmonics | <3%(Linear Load) | ||
DC Voltage Component | <1%Un(Linear Balanced Load) | ||
Unbalanced Load Capability | 110% Overload | ||
Rated Grid Frequency / Grid Frequency Range | 50Hz/45-55Hz(Configurable up to 60Hz) | ||
Efficiency | |||
Maximum Efficiency | 98.6% | ||
Protection | |||
DC Input Protection | Fuse | ||
AC Surge Protection | AC Typell | ||
Grid Monitoring/Insulation Monitoring | Y/Y | ||
Reverse Polarity Protection/Overheat Protection | Y/Y | ||
Basic Parameters | |||
Parallel Operation Function | Y | ||
Isolation Type | Transformerless Isolation | ||
IP Grade | IP21 | ||
Operating Temperature Range | -35°℃to +60℃(Derated Operation above 45°C) | ||
Relative Humidity Range | 0 to 100%(Condensation-Free) | ||
Cooling Method | Forced Intelligent Air Cooling | ||
Maximum Operating Altitude | 4000m(Derated Operation above 2000m) | ||
Installation Method | Wall-Mounted, Rack-Mounted | ||
Dimensions (W x H x D) | 420×132x600mm(Standard Enclosure with 3U Height) | ||
Weight | 30kg | ||
Display | LED, Upper Computer | ||
Communication Interface | WIFI/RS485/CAN/ Ethernet | ||
Communication Protocol | Modbus-RTU/Modbus-TCP/IEC61850/IEC104/CAN2.0B | ||
Grid Support | Active and Reactive Power Control, Power Slope Control | ||
Compliance with Standards | GB/T34133-2023,GB/T 34120-2023,IEC62477-1 |